Old 01-10-2007, 10:53 AM
Justaddwata Justaddwata is offline
Junior Member
 
Join Date: Jan 2007
Location: CT
Posts: 2
Default

The vast majority of splice breaks will occur at the end of the taper in the bury. (It is considered a good break when this occurs). Considering you are now removing the taper altogether I believe you are going to see a sizable loss in tensile. If you consider that a good portion of the 12 strands are going to be deviating from their normal path to allow for the exiting of the bury.

Given the fact that this is a life critical application and the rope will be taught before it is loaded (applying some high loads) I would approach Samson about having a tensile break done to an eye splice of this configuration. I am sure they would be happy to do it (it will certainly give them some valuable information) and it would certainly be better to know in advance than to have a failure occuring.

As for strength loss following the removal of the splice. I agree this should be minimal provided no damage has occurred to the yarns (and that the rope is indeed not overloaded at the revious splice points).
Reply With Quote
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is On


All times are GMT -7. The time now is 08:13 AM.


Powered by vBulletin® Version 3.6.7
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.